Content-Type: text/html; charset=utf-8
Content-Transfer-Encoding: 8bit
Hi Randy,
No problem, We will scrape it here.
Best Regards,
Marek D. Ringwelski
Mechanical Engineer
PolVac Corp.
Ph. (610) 625-1505 fax (610) 849-0395
www.polvac.com
Please reminder before sending future pumps to us. Drain all
oils that you do not want, except for dry pumps, as there will
be a fee for disposal. If unable please make arrangements prior
to pick/shipment. Pumps that have water cooling should be purged
of water as freezing of lines leads to expensive extra costs
that can easily be avoided. All pumps shipped out of PolVac Corp
will be purged of all water in the lines.
wrote:
Hi
Marek,
After
reviewing the extent of damages to this pump, we would like
to scrap it.
Knowing
the majority of this pump is still good, would you agree to
keeping the pump for parts to cover your time in assessment?
Thank-you,
Randy R. Clavet
Eastern
Region Field Service Manager
Ebara
Technologies, Inc.
Cell:
(207) 831-0718
Office:
(978) 465-1983
Fax:
(978) 465-5264
E-mail:
rclavet@ebaratech.com
From:
Leigh, Andrew
Sent: Friday, February 12, 2016 4:20 PM
To: Clavet, Randy
Subject: FW: Updated Estimate 3467 from PolVac
Corp.
Randy,
Please
make the call on this OS pump at Polvac. May not be worth
it…
Thanks,
-Andrew
From:
Sales Team [mailto:sales@polvac.com]
Sent: Friday, February 12, 2016 4:00 PM
To: Norcross, Alexandra
Cc: Leigh, Andrew
Subject: Updated Estimate 3467 from PolVac Corp.
Hi Ally,
The QDP40 experienced a lot of damage as the driven “Y” double
ball bearing failed. I have attached pictures of the damage
and also an updated quote for the parts that need to be
replaced to get system working again.
Please review the attached Quote/Estimate- 3467. Feel free to
contact us if you have any questions.
Please send Purchase Order to sales@polvac.com or fax
via 610-849-0395.
For Credit Card Sales, please provide an email to send an
electronic invoice to.
Credit Card sales are processed online through PayPal.
We look forward to working with you.
—
Thank You,
Marek D Ringwelski
PolVac Corp. Sales Team
Ph. (610) 625-1505 fax (610) 849-0395
www.polvac.com
Please reminder before sending future pumps to us. Drain all
oils that you do not want, except for dry pumps, as there
will be a fee for disposal. If unable please make
arrangements prior to pick/shipment. Pumps that have water
cooling should be purged of water as freezing of lines leads
to expensive extra costs that can easily be avoided. All
pumps shipped out of PolVac Corp will be purged of all water
in the lines.